Environmental Chamber – Benchtop, -35 – 150°C

The Benchtop Environmental Chamber (-35 to 150 °C) from Jeiotech delivers reliable, repeatable performance, making it a valuable addition to laboratory environments across South Africa. Its compact footprint optimizes bench space, while a specialized external humidification system ensures stable humidity control and simplifies maintenance. Thanks to superior thermal insulation and airtight sealing, the chamber maintains consistent temperature and humidity conditions, even during continuous or repeated testing. The double-sealed door structure enhances airtightness, preventing environmental fluctuations and ensuring accurate results.

Explore our range and learn more about optimizing your lab environment with solutions from Apex Scientific.

The Benchtop, -35 to 150 °C environmental chamber from Jeiotech offers high-performance environmental control for laboratory professionals across South Africa. Engineered for reliability and ease of use, it provides precise temperature and humidity conditions for demanding applications.

humidity graph

Stable Performance Zone: The solid yellow area represents the optimal zone where continuous temperature and humidity control is reliably maintained. This ensures reproducibility for long-term tests under defined environmental conditions.

Caution Zone: The hatched area on the left highlights the restricted operation range below 30 °C, where prolonged use (over 24 hours) is not recommended.

This performance envelope demonstrates the TH3-KE/ME strength in delivering consistent climate simulation, ideal for stability testing, material stress analysis, and quality control procedures in laboratory environments.

Convenience Features

A 5.6-inch color touch display controller simplifies operation, allowing you to view graphs and monitor the chamber’s status with ease. The water level check alerts you when refilling is needed, and the easy-cap water inlet makes maintenance quick and simple. Its efficient water supply and recirculation system reduce refill frequency—even during long-duration, high-humidity testing.

The chamber’s front-facing controls and tempered glass door improve usability and visibility. The door includes a heating wire and LED lamp, offering clear observation of your samples. LED status indicators make it easy to confirm operation at a glance. For flexibility, the system includes a cable port with a silicone plug for external equipment, and the removable refrigerator condenser grill allows easy cleaning.

 

Multifunction Control System

This system enables you to store, document, and back up test programs. An RS-232 port (standard) and optional RS-485 allow you to connect up to 32 chambers to a single PC. Temperature and humidity auto-tuning and calibration help ensure consistent, accurate performance.

Digital temperature and humidity control

The environmental chamber features a digital control interface for setting and monitoring temperature and relative humidity. Users can adjust operating setpoints and manage chamber operation through an intuitive control system.

Temperature and humidity auto-tuning, together with nine PID control zones, support stable and accurate environmental conditions. The multifunction controller also supports programmable operation, data storage, and communication with external monitoring systems.


To enhance control precision, the system divides PID zones into nine segments. You can also monitor and control the unit remotely using the LC Connected mobile app when paired with the LC GreenBox. The chamber supports data export in Excel or text format, making it easy to analyze results.

 

Outstanding Safety

Safety features include an electronic over-temperature shutdown and an independent temperature sensor with its own controller. This ensures the system safely shuts down in case of overheating.

Color touch display controller (5.6 inches)
Indicator LED Of Product Condition
Tempered glass window with wire heater and LED Lamp
Power Switch

A mechanical backup device limits the surface temperature to below 60 °C, even if electronic components fail. Additional safety systems include low and empty water level alerts, door-open warnings, and overcurrent protection. Each heater has a dedicated fuse, and the system automatically shuts off if the compressor current overloads.

Simplifying Humidity Testing with the Jeiotech TH3 Series

The Jeiotech TH3 Series benchtop humidity chamber offers user-friendly control with a 5.6-inch touchscreen, real-time graph monitoring, and intuitive LED indicators. Features like easy water refill, front-access controls, a heated glass door with LED lighting, and a removable condenser grill ensure convenience, efficient operation, and reliable performance—ideal for long-term, high-humidity testing in compact lab spaces.


For more insight and guidance, read our article, Environmental Chambers Explained: Temperature, Humidity & Stability Testing on the insights page at Apex Scientific. You’ll also find articles that explain various products and their laboratory applications.

Accessories

 

ModelTH3-ME-025TH3-ME-065TH3-ME-100
Interior dimensions
Chamber volume (L / cu ft)25 / 0.965 / 2.3100 / 3.5
Width (mm / inch)350 / 13.8400 / 15.7500 / 19.7
Depth (mm / inch)220 / 8.7330 / 13.0380 / 15.0
Height (mm / inch)350 / 13.8495 / 19.5530 / 20.9
Quantity of shelves (standard / max.)2 / 72 / 10
Distance between shelves (mm / inch)20 / 0.8
Max. load per shelf (kg / lbs)25 / 55.1
Permitted total load (kg / lbs)65 / 143.3
Cable port (Ø, mm / inch)50 / 2.0
Water tank capacity (L / cu ft)8 / 0.312 / 0.4
Weight (kg / lbs)80 / 176.4110 / 242.5130 / 286.6
Temperature data
Range without humidity (°C / °F)-20 to 100 / -4 to 212
Fluctuation (±°C / °F) 1)0.3 / 0.54
Variation (±°C / °F) 1)0.5 / 0.9
Heating time (0°C to 90°C) (min)50
Cooling time (90°C to 0°C) (min)55
Humidity data (※ Ref.: Temp./ Humid. control range graph)
Range (%RH)20 to 95
Fluctuation (±%RH) 1)1
Variation (±%RH) 1)3
Electrical data & Ordering information
Electrical requirements (AC230V, 1P, 50/60Hz, A)7.7A9.6A13.8A
Cat. No.AAH821132KAAH821232KAAH821332K

※ The above specifications are tested according to DIN 12880 and IEC 60068 standards.
※ Permissible environmental conditions are 18 – 30°C (recommended 20°C), 85% RH or less, under 2000m above sea level.
※ The DI water condition is pH 6.2 – 7.2 and the electrical conductivity is less than 20㎲/cm.
1) The set value is set under the conditions of 25°C, 60% RH.
2) Heating time condition value: TH3-KE (-40°C to 100°C), TH3-ME (-20°C to 100°C), TH3-PE (0°C to 100°C
3) Cooling time condition value: TH3-KE (20°C to -40°C), TH3-ME (20°C to -20°C), TH3-PE (20°C to 0°C)
※ Continuous operation below 10℃ without humidity control is available only for a limited duration.
(The allowable continuous operating time may vary depending on the operating environment.)
  

ModelTH3-ME-025TH3-ME-065TH3-ME-100
550 / 21.7 W (mm / inch)600 / 23.6 W (mm / inch)700 / 27.6 W (mm / inch)
880 / 34.6 D (mm / inch)1050 / 41.3 D (mm / inch)1110 / 43.7 D (mm / inch)
915 / 36.0 H (mm / inch)1060 / 41.7 H (mm / inch)1100 / 43.3 H (mm / inch)
211 / 8.3 A (mm / inch)276 / 10.9 A (mm / inch)
495 / 19.5 B (mm / inch)580 / 22.8 B (mm / inch)
170 / 6.7 E (mm / inch)
229 / 9.0 F (mm / inch)
SKUDescription
AAH821132KTH3-ME-025 Constant Temp. and Humidity Chamber (25L)
AAH821232KTH3-ME-065 Constant Temp. and Humidity Chamber (65L)
AAH821332KTH3-ME-100 Constant Temp. and Humidity Chamber (100L)

  

Accessories

SKUDescription
AAA8T610Cable Port (Ø 50mm) for TH3-KE-025, TH3-KE-065 and TH3-KE-100
AAA8T611Cable Port (Ø 80mm) for TH3-KE-065 and TH3-KE-100
00RTD0000679Wire Shelf for TH3-KE-025
00RTD0000680Wire Shelf for TH3-KE-065
00RTD0000681Wire Shelf for TH3-KE-100
AAA80602-6Perforated Shelf for TH3-KE-025
AAA80602-7Perforated Shelf for TH3-KE-065
AAA80602-8Perforated Shelf for TH3-KE-100
AAA80550Signal Lamp for TH3-KE-025, TH3-KE-065 and TH3-KE-100
AAA8T504Recorder (Paper) for TH3-KE-025, TH3-KE-065 and TH3-KE-100
AAA8T506Recorder (Digital) for TH3-KE-025, TH3-KE-065 and TH3-KE-100
AAA8T625Water Purifier for TH3-KE-025, TH3-KE-065 and TH3-KE-100
AAA80620Direct Water System for TH3-KE-025, TH3-KE-065 and TH3-KE-100
AAA80631Stand (1 Stage) for TH3-KE-025
AAA80632Stand (1 Stage) for TH3-KE-065
AAA80633Stand (1 Stage) for TH3-KE-100
AAA80634Stand (2 Stage) for TH3-KE-025
AAA80635Stand (2 Stage) for TH3-KE-065

Insights Article: Environmental Chambers Explained: Temperature, Humidity & Stability Testing

Product Enquiry Handbook: Environmental Chambers

Operating Manual

Product Enquiry

"*" indicates required fields

First Name*
Last Name*