Standard type that provides the device information intuitively (OF4-S)
- 3.5-Inch touch controller that enables intuitive control of the device.
- Wait on/Wait off timer setting allowing efficient test schedule management.
Reliable temperature control performance based on stable control mechanisms
- Wide temperature range of up to 250℃.
- Three-point temperature calibration that ensures hightemperature accuracy over a wide temperature range.
- Available to set the upper and lower temperature limit, alarm activated to quick response when occurring the deviation.
- Excellent temperature distribution through the formation of optimal airflow for uniform heat transfer.
(±1.9℃ or below at 100℃)
Convenient checking for the test progress and data
- RS-232/USB port and compatible software provided to enable easy device control and data management using PC. (option)
- Monitor and control via mobile app anytime, anywhere with LC Connected. (mobile monitoring system) (option)
- BMS communication port that helps monitor the device temperature on the building management system. (option)
Various safety features for improved user safety
- The upper vent hole releases effectively fume inside the oven when using local ventilation equipment. (OF4-03)
- Device surface not overheating even in operation at the highest temperature. (70℃ or below, at 250℃)
- Top-rated overheating protection system. (registration KR 10-0397583)
- Over temperature limit function.
- Equivalent to IEC protection Class II.
Structural and functional features for improved user convenience
- Recording the 12 most recent events, such as start/stop of operation, the operating time, and error occurrence.
- Stacking Kit (option) ensuring the safe fitting of one unit to another, thus doubling the amount of work done in a given area for improved space efficiency.
- Hands-free™ door system to allow users to easily open the door while carrying samples with both hands.
(±1.9℃ or below at 100℃)
Technical Specifications
Model | Solid door (without window) | OF4-03S | OF4-05S | OF4-10S | OF4-15S | |||
---|---|---|---|---|---|---|---|---|
Window door | OF4-03SW | OF4-05SW | OF4-10SW | OF4-15SW | ||||
Chamber volume (L/cu ft) | 26/0.92 | 61/2.15 | 112/3.96 | 147/5.19 | ||||
Temperature 1) | Range (℃/℉) | Amb. + 10~250 / Amb. + 18 ~ 482 | ||||||
Fluctuation at 100℃ (±℃/±℉) | 0.3/0.54 | 0.3/0.54 | 0.3/0.54 | 0.3/0.54 | ||||
Variation at 100℃ (±℃/±℉) | 1.4/2.52 | 1.9/3.42 | 1.7/3.06 | 1.5/2.70 | ||||
Heating time to 100℃ (min) | 8 | 10 | 14 | 15 | ||||
Recovery time at 100℃ (min) | 4 | 4 | 4 | 4 | ||||
Control Panel | 3.5inch TFT Color LCD | |||||||
Communication interface | USB, RS-232 (Option) | |||||||
Function | Recently event record | 12ea | ||||||
Dimensions | Interior (W x D x H, mm/inch) | 300 x 210 x 400 / 11.80 x 8.27 x 15.75 |
380 x 330 x 480 / 14.97 x 13.0 0x 18.90 |
485 x 350 x 655 / 19.09 x 13.78 x 25.79 |
550 x 376 x 710 / 21.65 x 14.80 x 27.95 |
|||
Exterior (W x D x H, mm/inch) | 478 x 527 x 604 / 18.82 X 20.75 X 23.78 |
558 x 648 x 684 / 21.97 X 25.51 X 26.93 |
663 x 677 x 859 / 26.1 X 26.65 X 33.82 |
728 x 704 x 914 / 28.66 X 27.72 X 35.98 |
||||
Net weight (kg/lbs) | 33/72.8 | 53/116.8 | 63/138.9 | 73/160.9 | ||||
Shelves | Quantity of shelves (Standard/max.) |
2/4 | 2/5 | 2/8 | 2/9 | |||
Max. Load per shelf (kg/lbs) | 30/66.1 | |||||||
Number of Air change per hour at 100 ℃ 2) | 123 | 22 | 18 | 11 | ||||
Electrical requirements (230V, 50/60Hz, A) | 6.4 | |||||||
Cat. No. | Solid door (without window) | AAH14115K | AAH14125K | AAH14135K | AAH14145K | |||
Window door | AAH14215K | AAH14225K | AAH14235K | AAH14245K | ||||
Electrical requirements (120V, 60Hz, A) | 12.3 | |||||||
Cat. No. | Solid door (without window) | AAH14116U | AAH14126U | AAH14136U | AAH14146U | |||
Window door | AAH14216U | AAH14226U | AAH14236U | AAH14246U |
2) This data was measured when the fan speed was set to Step 5. If the fan speed is set to Step 1 or Step 3, the number of air changes may decrease. (According to ASTM D 5374, reapproved 1999)
Exterior
Interior
Model | OF-03P | OF4-05P | OF4-10P | OF4-15P | |
---|---|---|---|---|---|
A: Maximum depth with door opened | 868 / 34.2 | 1060 / 41.7 | 1185 / 46.7 | 1271 / 50.0 | |
B: Maximum width with door opened | 695 / 27.4 | 809 / 31.9 | 958 / 37.7 | 1050 / 41.3 | |
C: Interior width | 300 / 11.8 | 380 / 15.0 | 485 / 19.1 | 550 /21.7 | |
D: Interior height | 400 / 15.7 | 480 / 18.9 | 655 / 25.8 | 710 / 28.0 | |
E: Interior depth | 210 / 8.3 | 330 / 13.0 | 350 / 13.8 | 376 / 14.8 | |
F: Shelve width | 266 / 10.5 | 346 / 13.6 | 451 / 17.8 | 516 / 20.3 | |
G: Shelve depth | 195 / 7.7 | 315 / 12.4 | 335 / 13.2 | 361 / 14.2 | |
H: Gap between shelf racks | 30 / 1.2 | 30 / 1.2 | 30 / 1.2 | 30 / 1.2 | |
I: Gap between uppermost shelve and interior ceiling | 80 / 3.1 | 90 / 3.5 | 88 / 3.5 | 85 / 3.3 | |
J: Space for sensor installation | 3.8 / 0.15 | 3.8 / 0.15 | 3.8 / 0.15 | 3.8 / 0.15 |