CAT Automatic Titrator has been designed to simply and precisely perform the widest range of potentiometric titrations, and has always been the first choice if you are looking for a very easy-to-use automatic titrator for any application. A special training or a deeper knowledge of automatic titration are not necessary to get precise and quick results. That and much more is exactly what the new generation of CAT stands for:
- High resolution pH/mV-measurement input for pH-, silver-,mV-electrodes and double platinum electrode
- Pt 100 temperature measurement input for automatic temperature compensation
- Pre-installed standard methods for alkalinity, total acidity in drinks, free and total SO2 in wine, chloride etc.
- Constant and progressive titration to equivalent points
- Titration to pH and mV-end points
- Automatic pH measurement (If the auto sampler is present)
Typical applications of water/wastewater and environmental analysis
- Automatic pH measurement
- Alkalinity (p+m value)
- Total kjeldahl nitrogen
- Chloride in wastewater
Typical applications of food analysis
- Salt content (chloride, sodium chloride)
- pH-value, total acidity in wine, drinks and other food products
- Ascorbic acid
- protein determination (Kjeldahl-nitrogen in milk and dairy products)
- Free SO2,total SO2 determination in wine
- Iodine and peroxide value
Standard methods
- Pre-installed standard methods for alkalinity, total acidity in drinks, chloride,SO2 in wine etc.
- Each standard method can be used directly or edited according to actual needs
- The commonly used titration method can be marked and set to the top,which is easy for operators to choose quickly.
Menu
Built-in system setting, date and time setting, calibration solution setting, operator setting, burette manual operation, creep pump manual operation, electrode lifting device manual setting, and continuous titration turntable manual setting function
Utility
Including: manual setting of cleaning steps, manual filling of burette,calibration program settings, pH measurement settings, titration results query, import, transfer and deletion, calibration reports and records
Titration curve
- During the titration process, the titration curve is displayed in real time,and the integral curve will be shown after the titration is finished
- After titration, display titration results, including starting values, ending values and calculation results
Features
Display | 4.3″ monochromatic LCD touch screen |
Burette dispensation accuracy | Syringe volume: 10mL (It is possible to install up to 2 burettes) |
Burette solution (steps) | 12000(means 0.83 μL at any step) |
Dispensation accuracy | <0.2% |
Dispensation repeatability | ±0.2% |
Peristaltic pumps | Interchangeable pump head (up 3 per unit), 1ml/sec. |
pH | Range:0-14pH, Accuracy:±0.02pH, Resolution:±0.01pH |
mV | Range:±2000mV, Accuracy:±2mV, Resolution:±0.1mV |
μA | Range:±10μA, Accuracy:±2μA, Resolution:±0.1μA |
Temperature | Range:0-100℃ , Accuracy:±1℃ , Resolution:±0.1℃ |
Utility procedures | 1. Priming 2.Cleaning 3.Electrode calibration |
Method template | EP, EQ, free SO2, total SO2 and double SO2 |
pH calibration | Buffer auto-recognize. Refusal defective electrodes. Notice expired calibration (to be set from 0 to 7 days). Temperature compensation with pt100 probe during pH calibration
a)1 buffer calibration (7) |
Communication | 1.Electrode port (x2) 2.Pt100 3.USB A 4.USB B 5.RS232 (for printer) 6.RS232 (for auto sampler) 7.Bluetooth (for external PC) |
Internal memory | Last 50 analyses and last 10 calibrations Up 30 methods Data export: (date, hour, operator ID, sample ID, method, result, titrant volume) a) To USB pen drive (file csv) b) To external pc (via dedicated |
Accessories | 1. Printer 2. Single analyses stand 3. 16 positions sampler 4. 35 positions micro-sampler 5. Auto-level adjuster 6. Automatic degasser 7. Software for data management on external PC |
Order Information CAT2 Automatic titrator with 16 position auto-sampler
Order No. | Model | Description |
CAT2-16-M1 | Basis set | Basic unit without electrode, Included CAT2, AS24 16 position auto-sampler (1), Stir bar(1),10ml burette(40),titration tube(2),power supply(1),1L glass bottle(2), GL45 and S40 adapter(2),drying tube(2). |
CAT2-16-M2 | For pH titration | CAT2-16-M1 with pH electrode and buffer solution |
CAT2-16-M3 | For Precipitation titration | CAT2-16-M1 with Ag electrode |
CAT2-16-M4 | For Redox titration | CAT2-16-M1 with Pt electrode |
CAT2-16-M5 | For Dead stop titration | CAT2-16-M1 with Double Platinum electrode |